IEAP - Institute of Experimental and Applied Physics CTU - Czech Technical University in Prague
Česky English
IEAP - Institute of Experimental and Applied Physics CTU - Czech Technical University in Prague
CTU - Czech Technical University in Prague
Grants  > Research Program 40: Usage of radionuclides and ionizing radiation.
Research Program 40: Usage of radionuclides and ionizing radiation.

The project is solved by several institutes of Czech Technical University in Prague (Departments of FNSPE, CRRC). Institute of Experimental and Applied Physics (IEAP) is involved in development and optimization of radiation detectors for various application fields. Different adaptations of semiconductor pixel detectors of Medipix family play important role. Research in IEAP follows these directions:

Other details are available in czech language only.



number
MSM 6840770040

duration
1.1.2007 - 31.12.2012

coordinator
Musílek Ladislav FNSPE CTU
responsible person
team members

Articles in Impacted Journals
(70)
Text format
Year

Ocenění Name Author Scientific journal OceněníYear
3D imaging of radiation damage in silicon sensor and spatial mapping of charge collection efficiency Jakůbek M.; Jakůbek J.; Žemlička J.; Platkevič M.; Havránek V.; Semian V. JINST 8 C03023 2013
Displacement tracking in single human trabecula with metal-plated micro-spheres using X-ray radiography imaging Jiroušek O.; Kytýř D.; Doktor T.; Krejčí F. Journal of Instrumentation 8 C02041 2013
Evaluation of local radiation damage in silicon sensor via charge collection mapping with the Timepix read-out chip Platkevič M.; Jakůbek J.; Havránek V.; Jakůbek M.; Semian V.; Žemlička J. JINST 8 C04001 2013
Linear energy transfer and track pattern recognition of secondary radiation generated in hadron therapy beam in a PMMA target Opalka L.; Granja C.; Jakůbek J.; Pospíšil S.; Šolc J.; Hartmann B.; Martisikova M.; Jaekel O. J.of Instrumentation JINST 8 (2013) C02047 2013
Multimodal imaging with hybrid semiconductor detectors Timepix for an experimental MRI-SPECT system Zajíček J.; Jakůbek J.; Burian M.; Vobecký M.; Fauler A.; Fiederle M.; Zwerger A. Journal of Instrumentation 2013
3D measurement of the radiation distribution in a water phantom in a hadron therapy beam Opalka L.; Granja C.; Hartmann B.; Jakůbek J.; Jaekel O.; Martisikova M.; Pospíšil S.; Solc J. J.of Instrumentation 7 (2012) C01085 2012
Pixel detector Timepix operated in pile-up mode for pulsed imaging with ultra-soft X-rays Krejčí F.; Jakůbek J.; Kroupa M.; Brůža P.; Pánek D. Journal of Instrumentation 7 C12013 2012
Probe and scanning system for 3D response mapping of pixelated semiconductor detector with X-rays and the timepix device Jakůbek M.; Jakůbek J.; Žemlička J.; Kroupa M.; Krejčí F. AIP Conf. Proc. 1423, pp. 461-466; doi:10.1063/1.3688846 2012
3D sensitive voxel detector of ionizing radiation based on Timepix device Soukup P.; Jakůbek J.; Vykydal Z. Journal of Instrumentation 6 C01060, doi: 10.1088/1748-0221/6/01/C01060 2011
Absorption and Phase X-ray Imaging Using Reflected Beam Jakůbek J. NIM A, 633-1, S172-S174, doi:10.1016/j.nima.2010.06.158 2011
Analogue signal from common electrode of pixelated detector for triggering and spectroscopy Platkevič M.; Jakůbek J.; Vykydal Z.; Granja C. Journal of Instrumentation 6 C11023 doi:10.1088/1748-0221/6/11/C11023 2011
Analysis of painted arts by energy sensitive radiographic techniques with the Pixel Detector Timepix Žemlička J.; Jakůbek J.; Kroupa M.; Hradil D.; Hradilová J.; Mislerová H. Journal of Instrumentation 6 C01066, doi: 10.1088/1748-0221/6/01/C01066 2011
Application of the Medipix2 technology to space radiation dosimetry and hadron therapy beam monitoring Pinsky L.; Stoffle N.; Jakůbek J.; Pospíšil S.; Leroy C.; Gutierrez A.;  H.; Yasuda N.; Uchihori Y. Nucl. Instr. Methods A, Volume 628, Issue 1, Pages 226-229, doi:10.1016/j.nima.2010.06.323 2011
Background capabilities of pixel detectors for double beta decay measurements Čermák P.; Štekl I.; Bočarov V.; Jakůbek J.; Pospíšil S.; Fiederle M.; Fauler A.; Zuber K.; Loaiza P.; Shitov Y.; Madathiparambil Jose J. NIM A 2011
Characterization of the Medipix3 pixel readout chip Ballabriga R.; Blaj G.; Campbell M.; Fiederle M.; Greiffenberg D.; Heijne E.; Llopart X.; Plackett R.; Procz S.; Tlustos L.; Tureček D.; Wong W. Journal of Instrumentation 6 C01052, doi: 10.1088/1748-0221/6/01/C01052 2011
Coincidence Imaging System with Electron Optics Kroupa M.; Jakůbek J.; Krejčí F.; Žemlička J.; Horáček M.; Radlička T.; Vlček I. Nucl. Instr. Methods A 633, Suppl. 1, S270-S273 2011
Design, implementation and first measurements with the Medipix2-MXR detector at the Compact Muon Solenoid experiment Ball A.; Bell A.; Butler A.; Pospíšil S.; Vykydal Z.; et al. Journal of Instrumentation 6 P08005 doi:10.1088/1748-0221/6/08/P08005 2011
Direct Observation of Decay of Radioactive Nuclei with Spatial and Time Coincidence Technique Jakůbek J.; Platkevič M.; Granja C.; Koester U.; Pospíšil S. Nucl. Instr. Methods A 633 (2011) S203-S205 2011
Energy sensitive Timepix silicon detector for electron imaging Esposito M.; Jakůbek J.; Mettivier G.; Pospíšil S.; Russo P.; Šolc J. NIM A, Vol. 652, Issue 1, 458-461, doi:10.1016/j.nima.2011.01.148 2011
Estimate of the neutron fields in ATLAS based on ATLAS-MPX detectors data Bouchami J.; Dallaire F.; Gutierrez A.; Idárraga J.; Král V.; Leroy C.; Pickard S.; Pospíšil S.; Scallon O.; Šolc J.; Suk M.; Tureček D.; Vykydal Z.; Žemlička J. Journal of Instrumentation 6 C01042, doi: 10.1088/1748-0221/6/01/C01042 2011
Evaluation of a YAG:Ce scintillation crystal based CCD X-ray imaging detector with the Medipix2 detector Tous J.; Blazek J.; Žemlička J.; Jakůbek J. JINST 6 C11011 doi:10.1088/1748-0221/6/11/C11011 2011
FITPix – Fast Interface for Timepix Pixel Detectors Kraus V.; Holík M.; Jakůbek J.; Kroupa M.; Soukup P.; Vykydal Z. Journal of Instrumentation 6 C01079, doi: 10.1088/1748-0221/6/01/C01079 2011
Fast neutron detection efficiency of ATLAS-MPX detectors for the evaluation of average neutron energy in mixed radiation fields Bouchami J.; Gutierrez A.; Holý T.; Král V.; Lebel C.; Leroy C.; Macana J.; Pospíšil S.; Scallon O.; Suk M.; Tartare M.; Teyssier C.; Vykydal Z.; Žemlička J. Nucl. Instr. and Meth. A, Volume 633, Supplement 1, Pages: S226-S230, doi: 10.1016/j.nima.2010.06.174 2011
Image processing for X-ray transmission radiography with 3D voxel detector Jandejsek I.; Soukup P.; Jakůbek J. JINST 6 C12061 doi:10.1088/1748-0221/6/12/C12061 2011
Influence of electromagnetic interference on the analog part of hybrid Pixel detectors Holík M.; Kraus V.; Granja C.; Jakůbek J.; Georgiev V.; Hromadka M.; Skala J.; Kubik Z. JINST 6 C12028, doi:10.1088/1748-0221/6/12/C12028 2011
MEDIPIX/TIMEPIX cosmic ray tracking on BEXUS stratospheric balloon flights Urbář J.; Scheirich J.; Jakůbek J. Nucl. Instr. Methods A, Vol. 633, Suppl. 1, p. S206-S209, doi:10.1016/j.nima.2010.06.168 2011
Measurement of pattern recognition efficiency of tracks generated by ionizing radiation in a Medipix2 device Bouchami J.; Gutierrez A.; Holý T.; Houdayer A.; Jakůbek J.; Lebel C.; Leroy C.; Macana J.; Martin J.; Pospíšil S.; Prak S.; Sabella P.; Teyssier C. Nucl. Instr. Methods A, Vol. 633, Suppl. 1, p. S187-S189, doi:10.1016/j.nima.2010.06.163 2011
Medipix2 based CdTe microprobe for dental imaging Vykydal Z.; Fauler A.; Fiederle M.; Jakůbek J.; Švestková M.; Zwerger A. Journal of Instrumentation 6 C12002 doi:10.1088/1748-0221/6/12/C12002 2011
Award for the first best poster Microradiography of biological samples with Timepix Dammer J.; Weyda F.; Benes J.; Sopko V.; Jakůbek J.; Vondracek V. JINST 6 C11005 doi:10.1088/1748-0221/6/11/C11005 2011
Past, Present and Future of the n_TOF Facility at CERN Chiaveri E.; Andriamonje S.; Calviani M.; Vykydal Z.; et al. Journal of the Korean Physical Society, Volume: 59, Issue: 2, Pages: 1620-1623, doi: 10.3938/jkps.59.1620 2011
Penetrating heavy ion charge and velocity discrimination with a TimePix-based Si detector (for space radiation applications) Pinsky L.; Empl A.; Gutierrez A.; Jakůbek J.; Kitamura H.; Miller J.; Leroy C.; Stoffle N.; Pospíšil S.; Uchihori Y.; Yasuda N.; Zeitlin C. Nucl. Instr. Methods A, Vol. 633, Suppl. 1, p. S190-S193, doi:10.1016/j.nima.2010.06.164 2011
Pixelman: a multi-platform data acquisition and processing software package for Medipix2, Timepix and Medipix3 detectors Tureček D.; Holý T.; Jakůbek J.; Pospíšil S.; Vykydal Z. Journal of Instrumentation 6 C01046, doi: 10.1088/1748-0221/6/01/C01046 2011
Precise Energy Calibration of Pixel Detector Working in Time-Over-Threshold Mode Jakůbek J. Nucl. Instr. Methods A, Volume 633, Supplement 1, May 2011, Pages S262-S266, doi:10.1016/j.nima.2010.06.183 2011
Quantized hard-x-ray phase vortices nucleated by aberrated nanolenses Pavlov K.; Paganin D.; Vine D.; Schmalz J.; Suzuki Y.; Uesugi K.; Takeuchi A.; Yagi N.; Kharchenko A.; Blaj G.; Jakůbek J.; Atissimo M.; Clark J. Physical Review A, Vol.83, Issue 1, 013813,doi: 10.1103/PhysRevA.83.013813 2011
Radiography in Engineering Practice Vavřík D.; Dammer J.; Jakůbek J.; Jeon I.; Jiroušek O.; Kroupa M.; Zlámal P. Nucl. Instr. Methods A, Vol. 633, Suppl. 1, p. S152-S155, doi:10.1016/j.nima.2010.06.152 2011
Remote control of ATLAS-MPX Network and Data Visualization Tureček D.; Holý T.; Pospíšil S.; Vykydal Z. Nucl. Instr. and Meth. A, Volume 633, Supplement 1, Pages: S45-S47, doi: 10.1016/j.nima.2010.06.117 2011
Selective detection of secondary particles and neutrons produced in ion beam therapy with 3D sensitive voxel detector Jakůbek J.; Granja C.; Hartmann B.; Jäkel O.; Martisikova M.; Opalka L.; Pospíšil S. JINST 6 C12010, doi:10.1088/1748-0221/6/12/C12010 2011
Single grating method for low dose 1-D and 2-D phase contrast X-ray imaging Krejčí F.; Jakůbek J.; Kroupa M. Journal of Instrumentation 6 C01073 2011
Slow-neutron-induced charged-particle emission-channeling-measurements with Medipix detectors Koester U.; Granja C.; Jakůbek J.; Uher J.; Vacík J. Nucl. Instr. Methods A 633 (2011) S267-S269 2011
Small Dosimeter based on Timepix device for International Space Station Tureček D.; Pinsky L.; Jakůbek J.; Vykydal Z.; Stoffle N.; Pospíšil S. Journal of Instrumentation 6 C12037, doi: 10.1088/1748-0221/6/12/C12037 2011
Study of the charge sharing in silicon pixel detector by means of heavy ionizing particles interacting with a Medipix2 device Bouchami J.; Gutierrez A.; Houdayer A.; Jakůbek J.; Lebel C.; Leroy C.; Macana J.; Martin J.; Platkevič M.; Pospíšil S.; Teyssier C. Nucl. Instr. Methods A. Vol. 607, Issue 1, 1 p. 196-198, doi:10.1016/j.nima.2009.03.147 2011
Tests of Lobster Eye Optics for Small Space X-ray Telescope Tichý V.; Barbera M.; Collura A.; Hromčík M.; Hudec R.; Inneman A.; Jakůbek J.; Maršík J.; Maršíková V.; Pína L.; Varisco S. Nucl. Instr. Methods A, Vol. 633, Suppl. 1, p. S169-S171, doi:10.1016/j.nima.2010.06.157 2011
The use of contrast agent for imaging biological samples Dammer J.; Weyda F.; Sopko V.; Jakůbek J. JINST 6 C01096, doi: 10.1088/1748-0221/6/01/C01096 2011
Three-dimensional dosimetry imaging of I-125 plaque for eye cancer treatment Weaver M.; Green J.; Petasecca M.; Lerch M.; Cutajar D.; Franklin D.; Jakůbek J.; Carolan M.; Conway M.; Pospíšil S.; Kron T.; Metcalfe P.; Zaider M.; Rosenfeld A. Nucl. Instr. Methods A, Vol. 633, Suppl. 1, p. S276-S278, doi:10.1016/j.nima.2010.06.187 2011
USB Lite-Miniaturized readout interface for Medipix2 detector Vykydal Z.; Jakůbek J. Nucl. Instr. and Meth. A, Volume 633, Supplement 1, Pages: S48-S49, doi: 10.1016/j.nima.2010.06.118 2011
X-Ray Fluorescence Imaging With the Medipix2 Single-Photon Counting Detector Uher J.; Harvey G.; Jakůbek J. IEEE Transactions on Nuclear Science, Vol. PP, Issue: 99, doi: 10.1109/TNS.2011.2173352 2011
X-ray Phase Contrast Imaging Using Single Absorption Coded Aperture Krejčí F.; Jakůbek J.; Kroupa M. Nucl. Instr. Methods A 633, Suppl. 1, 181 - 184 2011
X-ray beam hardening based material recognition in micro-imaging Uher J.; Jakůbek J.; Mayo S.; Stevenson A.; Tickner J. JINST 6 P08015 doi:10.1088/1748-0221/6/08/P08015 2011
From imaging to dosimetry: GEANT4-based study on the application of Medipix to neutron dosimetry Othman M.; Marinaro D.; Petasecca M.; Guatelli S.; Cutajar D.; Lerch M.; Prokopovich D.; Reinhard M.; Uher J.; Jakůbek J.; Pospíšil S.; Rosenfeld A. Radiation Measurements, Vol. 45, Issue 10, p. 1355-1358 2010
Neutron Dosimeter Development based on Medipix2 Othman M.; Petasecca M.; Guatelli S.; Uher J.; Marinaro D.; Prokopovich D.; Reinhard M.; Lerch M.; Jakůbek J.; Pospíšil S.; Rosenfeld A. IEEE Transactions on Nuclear Science 57 (6): 3456-3462 2010
Strain analysis of trabecular bone using time-resolved X-ray microtomography Jiroušek O.; Zlámal P.; Kytýř D.; Kroupa M. NIM A (accepted) 2010
Vectors and submicron precision: redundancy and 3D stacking in silicon pixel detectors Heijne E.; Ballabriga R.; Boltje D.; Campbell M.; Idarraga J.; Jakůbek J.; Leroy C.; Llopart X.; Tlustos L.; Plackett R.; Pospíšil S.; Tureček D.; Vermeulen J.; Visschers J.; Visser J.; Vykydal Z.; Wong W. Journal of Instrumentation 5 C06004, doi: 10.1088/1748-0221/5/06/C06004 2010
A coated pixel device TimePix with micron spatial resolution for UCN detection Jakůbek J.; Schmidt-Wellenburg P.; Geltenbort P.; Platkevič M.; Plonka-Spehr C.; Šolc J.; Soldner T. NIM A, Vol. 600, Issue 3, p. 651-656 2009
Comparison of Single Photon Counting and Charge-Integrating Detectors for X-ray High Resolution Imaging of Small Biological Objects Frallicciardi P.; Jakůbek J.; Vavřík D. NIM A, Vol. 607, Issue 1, p. 221-222 2009
Energy Sensitive X-ray Radiography and Charge Sharing Effect in Pixelated Detector Jakůbek J. NIM A, Vol. 607, Issue 1, p. 192-195 2009
Energy and Position Sensitive Pixel Detector Timepix for X-Ray Fluorescence Imaging Žemlička J.; Jakůbek J.; Kroupa M.; Tichy V. NIM A, Vol. 607, Issue 1, p. 202-204 2009
Enhancement of spatial resolution of roentgenographic methods Krejčí F.; Jakůbek J.; Dammer J.; Vavřík D. Nucl. Instr. Methods A 607, Issue 1, 208-211 2009
Position-sensitive spectroscopy of ultra-cold neutrons with Timepix pixel detector Jakůbek J.; Platkevič M.; Schmidt-Wellenburg P.; Geltenbort P.; Plonka-Spehr C.; Daum M. NIM A, Vol. 607, Issue 1, p. 45-47 2009
Radiogram enhancement and linearization using the beam hardening correction method Vavřík D.; Jakůbek J. NIM A, Vol. 607, Issue 1, p. 212-214 2009
Real-time in-vivo µ-imaging with Medipix2 Dammer J.; Frallicciardi P.; Jakůbek J.; Jakůbek M.; Pospíšil S.; Prenerová E.; Vavřík D.; Volter L.; Weyda F.; Zemek R. NIM A, Vol. 607, Issue 1, p. 205-207 2009
Pixel 2008 - Invited talk Semiconductor Pixel Detectors and their Applications in Life Sciences Jakůbek J. 2009 JINST 4 P03013 doi:10.1088/1748-0221/4/03/P03013 2009
The Medipix2-Based Network for Measurement of Spectral Characteristics and Composition of Radiation in ATLAS Detector Vykydal Z.; Bouchami J.; Campbell M.; Doležal Z.; Fiederle M.; Greiffenberg D.; Gutierrez A.; Heijne E.; Holý T.; Idarraga J.; Jakůbek J.; Král V.; Králík M.; Lebel C.; Leroy C.; Llopart X.; Maneuski D.; Nessi M.; O/'Shea V.; Platkevič M.; Pospíšil S.; Suk M.; Tlustos L.; Vichoudis P.; Visschers J.; Wilhelm I.; Žemlička J. Nucl. Instr. and Meth. A, Volume 607, Issue 1, Pages: 35-37, doi: 10.1016/j.nima.2009.03.104 2009
X-ray polarimetry by means od Compton scattering in the sensor of a hybrid photon counting detector Michel T.; Durst J.; Jakůbek J. NIMA Vol. 603, Issue 3, p. 384-392 2009
Detection of fast neutrons with the Medipix-2 pixel detector Uher J.; Jakůbek J.; Celine L.; Claude L.; Pospíšil S.; Škoda R.; Vykydal Z. Nucl. Instr. and Meth. A, Volume: 591, Issue:1, Pages: 71-74, doi: 10.1016/j.nima.2008.03.027 2008
Micrometric scale measurement of material structure moving utilizing μ-radiographic technique Vavřík D.; Jakůbek J.; Holý T. NIM A, Vol. 591, Issue 1, p. 24-27 2008
Microradiography of biologic objects using pixel detectors Dammer J.; Weyda F. Živa 6/2008, p 286-288 2008
Pattern recognition of tracks induced by individual quanta of ionizing radiation in Medipix2 silicon detector Holý T.; Erik H.; Jakůbek J.; Pospíšil S.; Uher J.; Vykydal Z. Nucl. Instr. and Meth. A, Volume: 591, Issue:1, Pages: 287-290, doi: 10.1016/j.nima.2008.03.074 2008
Pixel Detectors for Imaging with Heavy Charged Particles Jakůbek J.; Cejnarová A.; Holý T.; Pospíšil S.; Uher J.; Vykydal Z. Nucl. Instr. and Meth. A, Volume: 591, Issue:1, Pages: 155-158, doi: 10.1016/j.nima.2008.03.091 2008
Signal processor controlled USB2.0 interface for Medipix2 detector Platkevič M.; Bočarov V.; Jakůbek J.; Pospíšil S.; Tichy V.; Vykydal Z. Nucl. Instr. and Meth. A, Volume: 591, Issue:1, Pages: 245-247, doi: 10.1016/j.nima.2008.03.065 2008
X-Ray Fluorescence Imaging with Pixel Detectors Tichy V.; Holý T.; Jakůbek J.; Linhart V.; Pospíšil S.; Vykydal Z. Nucl. Instr. and Meth. A, Volume: 591, Issue:1, Pages: 67-70, doi: 10.1016/j.nima.2008.03.122 2008
Search
10th Anniversary of IEAP